FREEDOM
 
Model TS-16
Transducer Simulator
 
TS-16 Transducer Simulator

SPECIFICATIONS

Impedance: 350 ohms nominal
Output Ranges:
Fixed rotary switch: 0 to 3 mv/v in 15 steps of .2 mv/v
Output Accuracy:
Typically Max
+ 0.008% + 0.020% of full scale
+ 0.00024 mv/v + 0.00060 mv/v
or +1 microvolt, whichever is greater
Zero Offset:
Typically Max
+ 0.00009 mv/v + 0.0005 mv/v
or +1 microvolt, whichever is greater
Temp. Coefficient: + 5 ppm/°C
Excitation: 20v ac/dc max
Termination: Binding posts - accepts standard banana plug or up to No. 14 wire
Weight: 1Lbs.
Dimensions: 2.75"H x 3.14"D x 5.9"W
Enclosure: ABS Thermoplastic Case with Aluminum lid

Key Benefits

[Bullet] Made In USA
[Bullet] Highest Quality Components
[Bullet] 100% Tested
  • Call for OEM & Quantity Pricing
  • Custom Build Available

We manufacture and distribute a complete line of products for the scale industry.
Contact us and we can help you build your own Platform Scale, Tank Scale, or Batching System.
Home
Transducer Simulators
MODEL 0V MODEL 7 MODEL 7V TS-16 TS-16V  TS-16P TS-16VLW
sales@controlweigh.com
CONTROLWEIGH
Long Grove, IL 60047
(847) 540-8260
Fax: (847) 540-8270

 

Copyright © 2009 CONTROLWEIGH
Last modified: April 7, 2009